info@hifunipumps.com
+91-9909044581
images

PVC Copper 3 Core Round Cable

Cable Design

A Submersible Pump Cable is a specialized product to be used for submersible pump in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Rialto is designed and manufacured keeping in mind these factors to achieve the highest possible degree of reliability.

Application

  • Submersible Pump Cables are used as supply and control cables.
  • These cables are used in submersible pumps, underwater lighting, and floating switches etc.
  • Up to the depth of 500 m and water temperature up to +75°C.
  • These cables are ideal for outer installations in dry, moist and wet environments but however not suitable for explosive areas.
  • Cables are designed and manufactured to achieve the highest possible degree of reliability.
  • Standard length cable packing:
  • Coils 100, 200, 300 and 500, 1000m. in wooden reels

Features

  • Good insulation properties when submerged in winter
  • Quality backed by40 years’ experience in cable industry
  • Excellent resistant to moisture, abrasion, grace, oil
  • Longer Flex life
  • Excellent mechanical & electrical properties
  • Generally Conforming to :CENELEC HD 21, IEC 60227, UL-83, BS 6500, DIN VDE 0281, IS 694
  • Approved byGWSSB, GWRDC, TWAD, PHED, PSTC, ONGC, Railways, Mines etc
  • Tested bySGS, EIL, RITES, NPC
  • The area of installation is physically restrictive, and the environment is very hostile.
Cable Structure
Generally Conforms to :BS EN 50525, CENELEC HD 22.1.S2, DIN VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899
Copper :EC flexible copper generally conforms to IEC 60228, DIN VDE 0295,IS 8131
Insulation :Special PVC Core
Outer Sheath :Special PVC : Black, Blue

*Any color can be supplied as per the requirement and wish of the buyer.

Technical Data
Operating Temperature:-20°C to max. +80°C
Nominal Voltage:1100v
Test Voltage:3000v
Min. Bending Radius:6 x Cable diameter
Flame Propagation:Flame retardant test as per IEC 60332-1

Core Color : Core Identification

Color CodingAS Per BS EN 50525 & IEC 60227AS Per IS 694
3 CoreBlack, Light Blue and BrownRed, Yellow and Blue

Technical Data Table

PVC Round - 3 core

ConductorPVC InsulationTotal Thickness of Double PVC SheathConductor Resistance at 20°C (max)Current Rating at 40°C
Nominal Area inNos. & Dia. of wireNominal ThicknessNominal Core Dia.Nominal ThicknessApprox. Overall Dimensions
Sq. mm.Nos./mmmmmmmmmmΩ/kmAmps.
1.522/0.300.83.251.5010.012.1014
2.536/0.300.93.841.5011.07.4118
4.056/0.301.04.501.6013.04.9526
6.084/0.301.05.301.6014.63.3031
10.0140/0.301.06.502.018.01.9142
16.0224/0.301.08.002.021.21.2157
25.0350/0.301.210.102.1526.00.78072
35.0490/0.301.211.302.1528.30.55490
50.0703/0.301.413.602.2533.50.386115
70.0988/0.301.415.302.4537.80.272143
95.01349/0.301.618.002.4043.50.206165

Note: The Design and manufacturing of Hifuni Pumps Private Limited's Products are subject to constant improvement. The product supplied may differ in some details from specifications/illustrations given in this website. Kindly contact company's nearest branch office for proper model selection for your application.